Polycom 8-pin mini-DIN - DB-9 2457-10029-200 manual

View a manual of the Polycom 8-pin mini-DIN - DB-9 2457-10029-200 below. All manuals on ManualsCat.com can be viewed completely free of charge. By using the 'Select a language' button, you can choose the language of the manual you want to view.

  • Brand: Polycom
  • Product: Cables for computers and peripherals
  • Model/name: 8-pin mini-DIN - DB-9 2457-10029-200
  • Filetype: PDF
  • Available languages: English

Table of Contents

Page: 0
April 2007 Edition
3725-23979-002/A
Version 1.0.2
Integrator’s Reference Manual
for Polycom HDX Systems
Version 1.0.2
product pic here
Page: 1
Polycom Inc.
4750 Willow Road
Pleasanton, CA 94588-2708
USA
No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for
any purpose, without the express written permission of Polycom, Inc. Under the law, reproducing includes translating
into another language or format.
As between the parties, Polycom, Inc. retains title to, and ownership of, all proprietary rights with respect to the software
contained within its products. The software is protected by United States copyright laws and international treaty
provision. Therefore, you must treat the software like any other copyrighted material (e.g. a book or sound recording).
Every effort has been made to ensure that the information in this manual is accurate. Polycom, Inc. is not responsible
for printing or clerical errors. Information in this document is subject to change without notice.
Trademark Information
Polycom®, the Polycom logo design, and Vortex® are registered trademarks of Polycom, Inc., and Global Management
System™, MGC™, People+Content™, People On Content™, Polycom InstantDesigner™, Polycom PathNavigator™,
PowerCam™, Siren™, and VSX™ are trademarks of Polycom, Inc. in the United States and various other countries.
VISCA is a trademark of Sony Corporation. All other trademarks are the property of their respective owners.
Patent Information
The accompanying product is protected by one or more U.S. and foreign patents and/or pending patent applications
held by Polycom, Inc.
© 2007 Polycom, Inc. All rights reserved.
Page: 2
iii
Contents
1 Room Integration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Setting Up a Room for Video Conferencing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Room Layout Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Setting Up the Room for People On Content . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Integrating Video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Connecting Polycom Cameras . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Connecting Sony and ELMO Cameras . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
Connecting Vaddio and Canon Cameras . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13
Connecting BRCH700 Cameras . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14
Connecting Vaddio 300 Cameras . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15
Integrating Audio and Content . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16
Connecting a Computer to a Polycom HDX System . . . . . . . . . . . . . . . . . . . . 1-16
Connecting a Vortex Mixer to a Polycom HDX System . . . . . . . . . . . . . . . . . 1-17
2 Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Network Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
CAT 5e LAN Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
ISDN Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Analog Telephone (POTS) Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
V.35/RS-449/RS-530 Serial Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
V.35 NIC Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
V.35 and RS-366 Serial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
RS-449 and RS-366 Serial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
RS-530 with RS-366 Serial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Video and Camera Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
S-Video Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
BNC to S-Video Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
BNC to S-Video Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
DVI to VGA Monitor Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
HDMI Monitor Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
BNC Monitor Adapter Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
DVI-D Monitor Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
HDCI Analog Camera Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16
HDCI Camera Break-Out Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17
VCR/DVD Composite Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18
Page: 3
Integrator’s Reference Manual for Polycom HDX Systems
iv
Composite Video Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19
PowerCam Plus Primary Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
HDCI PowerCam Plus Adapter Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21
HDCI VISCA Adapter Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22
HDCI Sony VISCA Adapter Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-23
PowerCam Primary Camera Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-24
PowerCam Break-Out Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25
PowerCam Plus/VISCA Control Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26
PowerCam/VISCA Control Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-28
Audio Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29
Polycom HDX Microphone Array Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29
Polycom HDX Microphone Array Cable Adapter . . . . . . . . . . . . . . . . . . . . . . 2-30
Custom Cabling for Polycom HDX Microphones . . . . . . . . . . . . . . . . . . . . . . 2-31
Audio Adapter Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-34
Audio Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-35
Vortex Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-36
3.5mm Screw Cage Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-37
Subwoofer Volume Attenuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-38
Serial (RS-232) Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-39
RS-232 Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-39
Null Modem Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-41
3 Using the API . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Using the API with an RS-232 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Configuring the RS-232 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Starting an API Session via an RS-232 Interface . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Using the API with a LAN Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Using the API Controller Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
4 System Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
About the API Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Syntax Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Availability of Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
abk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
addressdisplayedingab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
adminpassword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
advnetstats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
alertusertone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
alertvideotone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
all register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
all unregister . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
allowabkchanges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13
allowcamerapresetssetup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14
allowmixedcalls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
Page: 4
Contents
v
allowusersetup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
answer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
areacode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
autoanswer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19
backlightcompensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20
basicmode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21
bri1enable, bri2enable, bri3enable, bri4enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22
briallenable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23
button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24
calldetailreport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-27
callencryption (deprecated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-28
callinfo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-29
callstate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30
callstats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-31
camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-32
cameradirection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
camerainput . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36
chaircontrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-37
colorbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-39
cmdecho . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-40
configchange (deprecated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-41
configdisplay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-42
configpresentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-43
confirmdiradd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-45
confirmdirdel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-46
contentauto . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-47
country . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-48
cts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-49
daylightsavings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-50
dcd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-51
dcdfilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-52
defaultgateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-53
dhcp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-54
dial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-55
dialchannels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-57
dialingdisplay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-58
diffservaudio, diffservfecc, diffservvideo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-59
dir . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-60
directory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-61
display (deprecated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-62
displayglobaladdresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-63
displaygraphics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-64
displayipext . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-65
displayipisdninfo (deprecated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-66
displayparams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-67
dns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-68
Page: 5
Integrator’s Reference Manual for Polycom HDX Systems
vi
dsr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-69
dsranswer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-70
dtr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-71
dualmonitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-72
dynamicbandwidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-73
e164ext . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-74
echo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-75
echocanceller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-76
enablefirewalltraversal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-77
enablersvp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-78
enablesnmp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-79
encryption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-80
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-81
farcontrolnearcamera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-82
farnametimedisplay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-83
flash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-84
gabk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-85
gabpassword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-86
gabserverip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-87
gatekeeperip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-88
gatewayareacode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-89
gatewaycountrycode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-90
gatewayext . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-91
gatewaynumber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-92
gatewaynumbertype . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-93
gendial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-94
gendialtonepots (deprecated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-95
generatetone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-96
get screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-97
getcallstate (deprecated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-98
gmscity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-99
gmscontactemail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-100
gmscontactfax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-101
gmscontactnumber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-102
gmscontactperson . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-103
gmscountry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-104
gmsstate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-105
gmstechsupport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-106
gmsurl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-107
h239enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-108
h323name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-109
h331audiomode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-110
h331dualstream . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-111
h331framerate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-112
h331videoformat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-113
h331videoprotocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-114
Page: 6
Contents
vii
hangup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-115
help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-116
history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-117
homecallquality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-118
homemultipoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-119
homerecentcalls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-120
homesystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-121
homesystemname . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-122
hostname . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-123
ipaddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-124
ipdialspeed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-125
ipisdninfo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-126
ipprecaudio, ipprecfecc, ipprecvideo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-127
ipstat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-128
isdnareacode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-129
isdncountrycode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-130
isdndialingprefix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-131
isdndialspeed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-132
isdnnum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-133
isdnswitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-134
keypadaudioconf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-135
language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-136
lanport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-137
linestate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-138
listen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-139
localdatetime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-140
marqueedisplaytext . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-141
maxgabinternationalcallspeed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-142
maxgabinternetcallspeed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-143
maxgabisdncallspeed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-144
maxtimeincall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-145
mcupassword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-146
meetingpassword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-147
monitor1 (deprecated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-148
monitor1screensaverouput . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-149
monitor2 (deprecated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-150
monitor2screensaverouput . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-151
mpautoanswer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-152
mpmode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-153
mtumode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-154
mtusize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-155
mute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-156
muteautoanswer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-157
natconfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-158
nath323compatible . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-159
nearloop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-160
Page: 7
Integrator’s Reference Manual for Polycom HDX Systems
viii
netstats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-161
nonotify . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-162
notify . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-163
ntpmode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-166
ntpserver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-167
numdigitsdid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-168
numdigitsext . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-169
pause . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-170
phone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-171
pip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-172
popupinfo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-173
preset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-174
pricallbycall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-175
prichannel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-176
pricsu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-178
pridialchannels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-179
priintlprefix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-180
prilinebuildout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-181
prilinesignal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-182
prinumberingplan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-183
prioutsideline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-184
priswitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-185
reboot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-186
recentcalls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-187
registerall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-188
registerthissystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-189
remotecontrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-190
remotemonenable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-192
repeat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-193
requireacctnumtodial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-194
roomphonenumber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-195
rs232 baud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-196
rs232 mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-197
rs232monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-198
rs366dialing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-199
rt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-200
rts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-201
screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-202
screencontrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-203
serialnum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-204
session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-205
setaccountnumber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-206
showpopup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-207
sleep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-208
sleeptime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-209
snmpadmin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-210
Page: 8
Contents
ix
snmpcommunity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-211
snmpconsoleip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-212
snmplocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-213
snmpsystemdescription . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-214
soundeffectsvolume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-215
spidnum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-216
st . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-217
subnetmask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-218
sysinfo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-219
systemname . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-220
tcpports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-221
techsupport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-222
teleareacode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-223
telecountrycode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-224
telenumber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-225
telnetmonitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-226
timediffgmt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-227
typeofservice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-228
udpports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-229
unregisterall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-230
usefixedports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-231
usegatekeeper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-232
usepathnavigator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-233
useroompassword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-234
v35broadcastmode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-235
v35dialingprotocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-236
v35num . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-237
v35portsused . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-238
v35prefix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-239
v35profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-240
v35suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-241
validateacctnum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-242
vcbutton . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-243
vcrrecordsource . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-244
version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-245
volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-246
vortex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-247
waitfor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-248
wake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-249
wanipaddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-250
webport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-251
whoami . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-252
A Room Design and Layout . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Room Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Walls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
Page: 9
Integrator’s Reference Manual for Polycom HDX Systems
x
Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
Ceiling Tiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4
Air Conditioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4
Interior Design and Finishes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5
Furniture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5
Acoustics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5
Room Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-6
Light Fixtures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-7
Room Preparation Conclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8
Audio Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8
Audio Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8
Audio Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-10
Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-10
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-10
Range/Frequency Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-11
Video Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-11
Video Projection for Use in Videoconference . . . . . . . . . . . . . . . . . . . . . . . . . A-12
Cameras . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-12
Room Control Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-13
B Commands that Prompt Restart . . . . . . . . . . . . . . . . . . . . . B-1
C Status Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
Status Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
B Channel Status Message Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
D Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1
Inputs/Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1
Audio Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1
DTMF Dialing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-3
Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-4
RS-232 Serial Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-7
Resolution vs. Call Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-8
Page: 10
1 - 1
1
Room Integration
Setting Up a Room for Video Conferencing
For detailed information about setting up a room for video conferencing, refer
to Room Design and Layout on page A-1.
Room Layout Examples
Use the following diagrams as examples for setting up a conference room with
Polycom® HDX systems. Polycom recommends that you contract an
experienced contractor to assure all the components operate as a single
cohesive system.
Small Conference Room
Video
Polycom Eagle Eye on
Polycom
Acoustic Panels
Acoustic Quality
Drapes
Dry Erase Board
Microphone
Media Center with
Built-In Speakers
Light
Flat Panel Monitor
Video
Light
Page: 11
Integrator’s Reference Manual for Polycom HDX Systems
1 - 2
Large Conference Room
Document Camera
Polycom
Power Outlets
Network Outlets
Flat Panel
Flat Panel
Polycom HDX system
Acoustic Panels
Monitor 1
Monitor 2
Media Center
Microphone
and Eagle Eye camera
Page: 12
Room Integration
1 - 3
Classroom
Computer
Document
Monitor 1
Monitor for
Polycom Camera 2
Table-Top Microphones
Teacher’s
Monitor 2
Touch Panel
VGA Out
Podium
Camera
HDX system
with Eagle
Eye camera
and Vortex
mixer
Page: 13
Integrator’s Reference Manual for Polycom HDX Systems
1 - 4
Setting Up the Room for People On Content
For the best results, follow these guidelines for setting up People On
Content™:
• Use the Polycom Eagle Eye camera.
• Create a flat, consistent background color using a screen or matte-finish
paint in green or blue. Make sure the background does not have shadows
or glare.
• Make sure that the background and the presenter are well lit. For example,
use a minimum of two 250 W halogen lights on the background and one
on the presenter.
• Experiment with different room and lighting arrangements until the best
results are achieved.
You can find more information about configuring and using People On
Content on the Polycom web site.
3 ft
250 W
250 W
250 W
Polycom HDX
system and
Eagle Eye
camera
Page: 14
Room Integration
1 - 5
Integrating Video
The following sections describe how to connect cameras to Polycom HDX
systems. After you connect a camera to a Polycom HDX system, refer to the
Administrator’s Guide for Polycom HDX Systems for information about
configuring the camera options in the user interface.
Connecting Polycom Cameras
You can connect Polycom HDX systems to a Polycom Eagle Eye, PowerCam™
or PowerCam Plus camera from Polycom, or to other supported cameras. You
must use a PowerCam Plus as the main camera, not as a secondary camera.
Refer to the release notes for a list of supported PTZ cameras.
Polycom Eagle Eye as the Main Camera up to 30 ft Away
You can connect a Polycom Eagle Eye camera (part number 8200-23600-001 or
8200-23610-001) to a Polycom HDX system as the main camera using:
• HDCI analog camera cable shown on page 2-16
1
1
Page: 15
Integrator’s Reference Manual for Polycom HDX Systems
1 - 6
Polycom Eagle Eye as the Second Camera up to 30 ft Away
You can connect a Polycom Eagle Eye camera (part number 8200-23600-001 or
8200-23610-001) to a Polycom HDX system as the second camera using:
• HDCI analog camera cable shown on page 2-16
• Power supply. Use only the approved power supply from Polycom (part
number 1465-52621-036). Do not exceed 12 Volts at 3 Amps.
2
DC IN 12V
2
Page: 16
Room Integration
1 - 7
Polycom Eagle Eye as the Main or Second Camera up to 100 ft Away
You can connect a Polycom Eagle Eye camera (part number 8200-23600-001 or
8200-23610-001) to a Polycom HDX system more than 30 ft away using:
• Two HDCI camera breakout cables shown on page 2-17
• Analog cables
• DB-9 serial cable
• Power supply. Use only the approved power supply from Polycom (part
number 1465-52621-036). Do not exceed 12 Volts at 3 Amps.
DC IN 12V
Optional,up to 100 ft
Page: 17
Integrator’s Reference Manual for Polycom HDX Systems
1 - 8
PowerCam as the Main Camera up to 10 ft Away
You can connect a PowerCam (part number 2215-50370-001) to a Polycom HDX
system as the main camera up to 10 ft away using:
• A—PowerCam Primary cable shown on page 2-24
• B—HDCI PowerCam Plus adapter cable shown on page 2-21
PowerCam as the Secondary Camera
The following kits are available, which include the power supply, PowerCam
Break-Out cable, PowerCam/VISCA Control cable, and S-Video cable:
• 7230-22231-001 (50 ft)
• 7230-22232-001 (100 ft)
1
1
A
B
Page: 18
Room Integration
1 - 9
You can connect a PowerCam (part number 2215-50370-001) to a Polycom HDX
system as the second camera using:
• A—PowerCam Break-Out cable shown on page 2-25
• B—PowerCam/VISCA Control cable shown on page 2-26
• C—S-Video cable shown on page 2-9
• D—HDCI PowerCam Plus adapter cable shown on page 2-21
• Power Supply (part number 1465-52621-036)
2
2
A
B C
D
Page: 19
Integrator’s Reference Manual for Polycom HDX Systems
1 - 10
You can connect a PowerCam (part number 2215-50370-001) to a Polycom HDX
system as the third camera using:
• A—PowerCam Break-Out cable shown on page 2-25
• B—8-pin mini-DIN to DB-9 cable shown on page 2-27
• C—S-Video cable shown on page 2-9
• D—S-Video to BNC adapter shown on page 2-11
• Power Supply (part number 1465-52621-036)
If you connect a PTZ camera to a serial port, configure the following settings
on the Serial Ports screen:
1. Set RS-232 Mode to Camera PTZ.
2. Set Camera Control to the camera input you are using.
IOIOIO
VCR/DVD
3
IOIOIO
VCR/DVD
3
Y C
B C
A
D
Page: 20
Room Integration
1 - 11
PowerCam Plus as the Main Camera up to 10 ft Away
You can connect a PowerCam Plus (part number 2215-50200-001) to a Polycom
HDX system as the main camera up to 10 ft away using:
• A—PowerCam Plus Primary cable shown on page 2-20
• B—HDCI PowerCam Plus adapter cable shown on page 2-21
1
1
B
A
Polycom HDX systems do not support automatic camera tracking with the
PowerCam Plus camera.
Page: 21
Integrator’s Reference Manual for Polycom HDX Systems
1 - 12
Connecting Sony and ELMO Cameras
Refer to the release notes for a list of supported Pan/Tilt/Zoom (PTZ)
cameras.
To connect a Sony or ELMO PTZ camera to a Polycom HDX system as the main
or second camera:
You can connect a Sony or ELMO PTZ camera to a Polycom HDX system
using:
• A—HDCI Sony VISCA camera adapter cable shown on page 2-23
• B—S-Video cable (optional)
• C—VISCA cable (optional)
Optional,up to 100 ft
A
B
C
Page: 22
Room Integration
1 - 13
Connecting Vaddio and Canon Cameras
Refer to the release notes for a list of supported Pan/Tilt/Zoom (PTZ)
cameras.
To connect a Vaddio or Canon PTZ camera to a Polycom HDX system as the main
or second camera:
You can connect a Vaddio 70, Vaddio 100, or Canon (with VISCA cable shoe)
PTZ camera to a Polycom HDX system using:
• A—HDCI VISCA adapter cable shown on page 2-22
• B—DB-9 serial cable (optional)
• C—S-Video cable (optional)
Optional,up to 100 ft
A
B
C
Page: 23
Integrator’s Reference Manual for Polycom HDX Systems
1 - 14
Connecting BRCH700 Cameras
Refer to the release notes for a list of supported Pan/Tilt/Zoom (PTZ)
cameras.
To connect a BRCH700 PTZ camera to a Polycom HDX system as the main or
second camera:
You can connect a BRCH700 PTZ camera to a Polycom HDX system using:
• A—DVI to VGA cable shown on page 2-12
• B—8-pin mini-DIN to DB-9 cable shown on page 2-27
• C—VGA cable (optional)
Optional,up to 100 ft
A
B
C
IOIOIO
IOIOIO
Page: 24
Room Integration
1 - 15
Connecting Vaddio 300 Cameras
Refer to the release notes for a list of supported Pan/Tilt/Zoom (PTZ)
cameras.
To connect a Vaddio 300 PTZ camera to a Polycom HDX system as the main or
second camera:
You can connect a Vaddio 300 PTZ camera to a Polycom HDX system using:
• A—HDCI VISCA adapter cable shown on page 2-22
• B—DB-9 serial cable (optional)
• C—S-Video cable (optional)
Optional,up to 100 ft
Quick-Connect
Box
RJ45
A
B
C
Page: 25
Integrator’s Reference Manual for Polycom HDX Systems
1 - 16
Integrating Audio and Content
Connecting a Computer to a Polycom HDX System
Connect a Polycom HDX system to a computer using:
• DVI to VGA cable shown on page 2-12
• Audio adapter cable on page 2-34
• 3.5 mm stereo to RCA adapter cable
When you connect a computer to video input 4 and audio input 4 on a Polycom
HDX 9004, audio from input 4 is muted unless video input 4 is selected as a video
source.
2
1
PC CARD
100-240VAC 50/60Hz 4A
LAN
IR
5
4
3 VCR/DVD
1
4
Y C
3 VCR/DVD
Y C
VCR/DVD
3
4
3 VCR/DVD
1
2
Y C
1
2
1
IOIOIO
Y C
4
4
4
2
1
PC CARD
100-240VAC 50/60Hz 4A
LAN
IR
3 VCR/DVD
1
4
Y C
3 VCR/DVD
Y C
VCR/DVD
3
3 VCR/DVD
1
2
Y C
1
1
IOIOIO
Y C
1
Polycom HDX 9004
Polycom HDX 9001 or HDX 9002
Page: 26
Room Integration
1 - 17
Connecting a Vortex Mixer to a Polycom HDX System
Connect a Polycom HDX system to the Vortex mixer using:
• Vortex cable shown on page 2-36
Polycom strongly recommends using Polycom InstantDesigner™ to get started with
your Polycom Vortex® mixer integration. InstantDesigner resolves many common
issues with connections and configuration settings.
To use a Polycom HDX system with audio input from a Vortex mixer, set the Input
Type to Line Input and disable Echo Canceller.
IOIOIO
A B
A B
2
1
PC CARD
100-240VAC 50/60Hz 4A
LAN
IR
5
4
3 VCR/DVD
1
4
Y C
3 VCR/DVD
Y C
VCR/DVD
3
4
3 VCR/DVD
1
2
Y C
1
2
1
IOIOIO
Y C
1 1
Page: 27
Integrator’s Reference Manual for Polycom HDX Systems
1 - 18
Page: 28
2 - 1
2
Cables
This chapter includes information about cables that can be used with a
Polycom HDX system. Please note that drawings and part numbers are
provided for reference only. Compliance information is provided for the
Restriction of certain Hazardous Substances Directive (RoHS).
Network Cables
CAT 5e LAN Cable
This cable connects a Polycom HDX system to the LAN. It has orange RJ-45
connectors on both ends. It meets category 5e requirements and is wired
according to EIA/TIA-568B. The maximum approved length for this cable is
100 ft (30 m) on an 802 network.
Length Part Number RoHS Compliant
12 ft (3.6 m) 2457-23537-001 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
T568B Pair
Page: 29
Integrator’s Reference Manual for Polycom HDX Systems
2 - 2
ISDN Cable
This cable connects a Polycom HDX system to a BRI or PRI line. It has clear
RJ-45 connectors on both ends and is used with all Polycom HDX systems that
have ISDN capability. The maximum approved length for this cable is 50 ft
(15 m).
PRI Pin Assignments
The following illustration and table show the pin assignments for the PRI port
on the Polycom HDX system.
Length Part Number RoHS Compliant
20 ft (6.6 m) 2457-08548-001 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Pin 8
Pin 1
Signal Name
Receive Ring
Receive Tip
No Connection
Transmit Ring
Transmit Tip
No Connection
No Connection
No Connection
Pin
1
2
3
4
5
6
7
8
Page: 30
Cables
2 - 3
Analog Telephone (POTS) Cable
This cable connects a Polycom HDX system to an analog telephone line. It has
pink RJ-11 connectors on both ends. The maximum approved length for this
cable is 100 ft (30 m).
Length Part Number RoHS Compliant
12 ft (3.6 m) 2457-20071-001 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Page: 31
Integrator’s Reference Manual for Polycom HDX Systems
2 - 4
V.35/RS-449/RS-530 Serial Adapter
This adapter is used when connecting a Polycom HDX system to other
third-party network equipment. It adapts the 68-pin interface to an industry
standard 44-pin interface used by some network interface equipment. It is
used with Polycom HDX systems that have a V.35/RS-449/RS-530 serial
network interface card (NIC) installed.
Length Part Number RoHS Compliant
6 in (15.23 cm) 2457-21264-200 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Notes (direction from V.35 module (DTE))
68 pin Signal Name Signal Type From card Function V.35 RS530-DB25 RS4449-DB37 RS366-DB25
Shield V.35/RS449/RS530 A 19 7,18,19#
12 Receive Data A Differential in V.35/RS449/RS530 R 3 6
11 Receive Data B Differential in V.35/RS449/RS530 T 16 24
10 Send Timing A Differential in V.35/RS449/RS530 Y 15 5
9 Send Timing B Differential in V.35/RS449/RS530 AA 12 23
29 Data Set Ready (DSR) Single Ended in V.35 E
28 Request To Send (RTS) Single Ended out V.35 C
27 Data Terminal Ready (DTR) Single Ended out V.35 H
34 Digit Present (DPR) Single Ended out RS366 2
24 Abandon Call/Retry (ACR) Single Ended in RS366 3
32 Call Request (CRQ) Single Ended out RS366 4
26 Present Next Digit (PND) Single Ended in RS366 5
21 Data Line Occupied (DLO) Single Ended in RS366 22
14 Receive Timing A Differential in V.35/RS449/RS530 V 17 8
13 Receive Timing B Differential in V.35/RS449/RS530 X 9 26
8 Terminal Timing A Differential out V.35/RS449/RS530 U 24 17
7 Terminal Timing B Differential out V.35/RS449/RS530 W 11 35
15 Request To Send (RTS) A Differential out RS449/RS530 4 7
16 Request To Send (RTS) B Differential out RS449/RS530 19 25
35** Receive Common Gnd RS449 20
20 BCD Dial Digit Bit 1 (NB1) Single Ended out RS366 14
19 BCD Dial Digit Bit 2 (NB2) Single Ended out RS366 15
23 BCD Dial Digit Bit 4 (NB4) Single Ended out RS366 16
25 BCD Dial Digit Bit 8 (NB8) Single Ended out RS366 17
2** Signal Ground Gnd V.35/RS366 B 7,18,19
6 Send Data A Differential out V.35/RS449/RS530 P 2 4
5 Send Data B Differential out V.35/RS449/RS530 S 14 22
reserved (Ascend select line)
63 Clear To Send (CTS) A Differential in RS449/RS530 5 9
64 Clear To Send (CTS) B Differential in RS449/RS530 13 27
61 Data Mode (DM-DSR) A Differential in RS449/RS530 6 11
62 Data Mode (DM-DSR) B Differential in RS449/RS530 22 29
65 Receiver Ready (RR-DCD) A Differential in RS449/RS530 8 13
66 Receiver Ready (RR-DCD) B Differential in RS449/RS530 10 31
4** Send Common Gnd RS530 7 37
33 Data Carrier Detect (DCD) Single Ended in V.35 F
18 Terminal Ready (TR-DTR) A Differential out RS449/RS530 20 12
17 Terminal Ready (TR-DTR) B Differential out RS449/RS530 23 30
3 V.35 Cable Connected ground to indicate a V.35 cable is attached 7,18,19*
1 RS449 Cable Connected ground to indicate a RS449 cable is attached 7,18,19^#
22 Distant Station Connected (DSC) Single Ended in RS366 13
30 Clear To Send (CTS) Single Ended in V.35 D
31 Ring Indicate (RI) (Incoming Call) Single Ended in V.35/RS449 J 15
reserved (Ascend select line)
68 LOS A Differential out RS530 crypto 18 3
67 LOS B Differential out RS530 crypto 21 21
* For V.35, connect pin 3 of 68 pin connector to ground
^For RS449, connect pin 1 of 68 pin connector to ground
#For RS530, connect pins 1 and 3 of 68 pin connector to ground
** Gnd pins are 2,4, 35-60
Peripheral Link
V.35 HD-68 Pinout
Page: 32
Cables
2 - 5
V.35 NIC Cable
This cable connects a Polycom HDX system to Ascend network equipment. It
is used with the V.35/RS-449/RS-530 serial adapter on page 2-4 to connect to
network equipment that has the HD-44 pin interface. It has HD-44 M
connectors on both ends and is used with Polycom HDX systems that have a
serial network interface card (NIC) installed.
Length Part Number RoHS Compliant
5 ft (1.65 m) 2457-10608-001 —
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Page: 33
Integrator’s Reference Manual for Polycom HDX Systems
2 - 6
V.35 and RS-366 Serial Cable
This cable connects a Polycom HDX system to third-party network equipment.
It is used with the V.35/RS-449/RS-530 serial adapter on page 2-4 to connect
to network equipment that has a V.35/RS-366 interface. It is HD-44 M to “Y”
Winchester 34M/RS-366 DB-25M and is used with Polycom HDX systems that
have a serial network interface card (NIC) installed.
Length Part Number RoHS Compliant
5 ft (1.65 m) 2457-10609-001 —
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Page: 34
Cables
2 - 7
RS-449 and RS-366 Serial Cable
This cable connects a Polycom HDX system to third-party network equipment.
It is used with the V.35/RS-449/RS-530 serial adapter on page 2-4 to connect
to network equipment that has an RS-449/RS-366 interface. It is HD-44 M to
“Y” RS-449 DB-37M/RS-366 DB-25M and is used with Polycom HDX systems
that have a serial network interface card (NIC) installed.
Length Part Number RoHS Compliant
5 ft (1.65 m) 2457-10610-001 —
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Page: 35
Integrator’s Reference Manual for Polycom HDX Systems
2 - 8
RS-530 with RS-366 Serial Cable
This cable connects a Polycom HDX system to third-party network equipment.
It is used with the V.35/RS-449/RS-530 serial adapter on page 2-4 to connect
to network equipment that has an RS-530/RS-366 interface. It is HD-68M to
“Y” DB-25M and is used with Polycom HDX systems that have a serial
network interface card (NIC) installed.
Length Part Number RoHS Compliant
5 ft (1.65 m) 2457-21263-001 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Peripheral Link V.35 HD-68 Pinout Notes (direction from V.35 module (DTE))
68 pin Signal Name Signal Type From card Function RS530-DB25 RS366-DB25
Shield V.35/RS449/RS530 7,18,19#
12 Receive Data A Differential in V.35/RS449/RS530 3
11 Receive Data B Differential in V.35/RS449/RS530 16
10 Send Timing A Differential in V.35/RS449/RS530 15
9 Send Timing B Differential in V.35/RS449/RS530 12
29 Data Set Ready (DSR) Single Ended in V.35
28 Request To Send (RTS) Single Ended out V.35
27 Data Terminal Ready (DTR) Single Ended out V.35
34 Digit Present (DPR) Single Ended out RS366 2
24 Abandon Call/Retry (ACR) Single Ended in RS366 3
32 Call Request (CRQ) Single Ended out RS366 4
26 Present Next Digit (PND) Single Ended in RS366 5
21 Data Line Occupied (DLO) Single Ended in RS366 22
14 Receive Timing A Differential in V.35/RS449/RS530 17
13 Receive Timing B Differential in V.35/RS449/RS530 9
8 Terminal Timing A Differential out V.35/RS449/RS530 24
7 Terminal Timing B Differential out V.35/RS449/RS530 11
15 Request To Send (RTS) A Differential out RS449/RS530 4
16 Request To Send (RTS) B Differential out RS449/RS530 19
35** Receive Common Gnd RS449
20 BCD Dial Digit Bit 1 (NB1) Single Ended out RS366 14
19 BCD Dial Digit Bit 2 (NB2) Single Ended out RS366 15
23 BCD Dial Digit Bit 4 (NB4) Single Ended out RS366 16
25 BCD Dial Digit Bit 8 (NB8) Single Ended out RS366 17
2** Signal Ground Gnd V.35/RS366 7,18,19
6 Send Data A Differential out V.35/RS449/RS530 2
5 Send Data B Differential out V.35/RS449/RS530 14
reserved (Ascend select line)
63 Clear To Send (CTS) A Differential in RS449/RS530 5
64 Clear To Send (CTS) B Differential in RS449/RS530 13
61 Data Mode (DM-DSR) A Differential in RS449/RS530 6
62 Data Mode (DM-DSR) B Differential in RS449/RS530 22
65 Receiver Ready (RR-DCD) A Differential in RS449/RS530 8
66 Receiver Ready (RR-DCD) B Differential in RS449/RS530 10
4** Send Common Gnd RS530 7
33 Data Carrier Detect (DCD) Single Ended in V.35
18 Terminal Ready (TR-DTR) A Differential out RS449/RS530 20
17 Terminal Ready (TR-DTR) B Differential out RS449/RS530 23
3 V.35 Cable Connected ground to indicate a V.35 cable is attached 7,18,19*
1 RS449 Cable Connected ground to indicate a RS449 cable is attached 7,18,19^#
22 Distant Station Connected (DSC) Single Ended in RS366 13
30 Clear To Send (CTS) Single Ended in V.35
31 Ring Indicate (RI) (Incoming Call)Single Ended in V.35/RS449
reserved (Ascend select line)
68 LOS A Differential out RS530 crypto 18
67 LOS B Differential out RS530 crypto 21
* For V.35, connect pin 3 of 68 pin connector to ground
^For RS449, connect pin 1 of 68 pin connector to ground
#For RS530, connect pins 1 and 3 of 68 pin connector to ground
** Gnd pins are 2,4, 35-60
Page: 36
Cables
2 - 9
Video and Camera Cables
S-Video Cable
These cables connect a Polycom HDX system to a monitor or camera. They
have yellow 4-pin mini-DIN connectors on both ends and are used with all
Polycom HDX systems. The maximum approved length for this cable is 200 ft
(60 m).
Length Part Number RoHS Compliant
25 ft (7.6 m) 2457-08409-002 Yes
8 ft (2.4 m) 2457-08410-002 Yes
50 ft (15 m) 2457-09204-200 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
MINI-DIN MALE 4 POS.( x2 )
P3 P4
P1 P2
25 FEET +/- 2"
P3 P4
P1 P2
Page: 37
Integrator’s Reference Manual for Polycom HDX Systems
2 - 10
BNC to S-Video Cable
This cable connects S-Video devices to a Polycom HDX system. It is 4-pin male
mini-DIN to dual BNC. The maximum approved length for this cable is 100 ft
(30 m).
Length Part Number RoHS Compliant
6 ft (1.8 m) 2457-21489-200 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Dimensions are in millimeters
Page: 38
Cables
2 - 11
BNC to S-Video Adapter
This adapter may be required when connecting standard S-Video cables to a
Polycom HDX system. It is dual BNC to 4-pin female mini-DIN.
Length Part Number RoHS Compliant
1 ft (.3 m) 2457-21490-200 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Dimensions are in millimeters
Page: 39
Integrator’s Reference Manual for Polycom HDX Systems
2 - 12
DVI to VGA Monitor Cable
This cable connects a Polycom HDX system DVI-I output to a VGA monitor. It
can also be used to connect a computer to one of the DVI-I video inputs on a
Polycom HDX system. It is male DVI-A to male HD-15.
Length Part Number RoHS Compliant
9 ft 10 in (3 m) 2457-23792-001 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Page: 40
Cables
2 - 13
HDMI Monitor Cable
This cable connects the Polycom HDX system DVI-I output to an HDMI
monitor. It is male DVI-D to male HDMI.
Length Part Number RoHS Compliant
9 ft 10 in (3 m) 2457-23905-001 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Page: 41
Integrator’s Reference Manual for Polycom HDX Systems
2 - 14
BNC Monitor Adapter Cable
This cable connects the Polycom HDX system DVI-I output to a variety of
analog display devices with composite, S-Video, component YPbPr, or
RGBHV inputs. It is male DVI-A to five female BNC connectors.
Length Part Number RoHS Compliant
1 ft (0.3 m) 2457-23533-001 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Page: 42
Cables
2 - 15
DVI-D Monitor Cable
This cable connects a Polycom HDX system DVI-I output to a DVI-D monitor.
It is male DVI-D on both ends.
Length Part Number RoHS Compliant
9 ft 10 in (3 m) 2457-23793-001 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Page: 43
Integrator’s Reference Manual for Polycom HDX Systems
2 - 16
HDCI Analog Camera Cable
This cable connects a Polycom HDX system to a Polycom Eagle Eye camera. It
has male HDCI connectors on both ends.
Length Part Number RoHS Compliant
9 ft 10 in (3 m) 2457-23180-003 Yes
33 ft (10 m) 2457-23180-010 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Page: 44
Cables
2 - 17
HDCI Camera Break-Out Cable
This cable breaks out the HDCI camera cable video and control signals to
standard interfaces. The five BNC connectors can be used to carry composite
video, S-Video, or analog component YPbPr video. The DB-9 connector is used
to connect to PTZ camera control interfaces. It is male HDCI to five female
BNC and one female DB-9.
Length Part Number RoHS Compliant
1ft (0.3 m) 2457-23521-001 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Page: 45
Integrator’s Reference Manual for Polycom HDX Systems
2 - 18
VCR/DVD Composite Cable
This cable connects a Polycom HDX system to a VCR or DVD player. It has
triple RCA connectors on both ends. The Polycom HDX system requires a
female RCA to male BNC adapter for the yellow video RCA connector, and the
Audio Adapter Cable on page 2-34. The maximum approved length for this
cable is 50 ft (15 m).
Length Part Number RoHS Compliant
8 ft (2.6 m) 2457-08412-001 —
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Page: 46
Cables
2 - 19
Composite Video Cable
This cable connects a Polycom HDX system to a monitor or camera. It has
single yellow RCA connectors on both ends. The Polycom HDX system
requires a female RCA to male BNC adapter in order to connect to composite
input or output. The maximum approved length for this cable is 100 ft (30 m).
Length Part Number RoHS Compliant
25 ft (7.6 m) 2457-09207-001 —
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Page: 47
Integrator’s Reference Manual for Polycom HDX Systems
2 - 20
PowerCam Plus Primary Cable
This cable connects a Polycom HDX system to a Polycom PowerCam Plus
camera using the HDCI PowerCam Plus adapter cable on 2-21. It has 4-pin
mini-DIN and DB-15 connectors on both ends.
Length Part Number RoHS Compliant
9 ft 10 in (3 m) 1457-50105-002 Yes
30 ft (9 m) 1457-50105-230 Yes
50 ft (15 m) 1457-50105-250 Yes
100 ft (30 m) 1457-50105-300 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
1 5 7
6
4
2 3 8
15
14
12
10
9 11 13
1
3 4
2
Front View
of Connector
1
3 4
2
1 5 7
6
4
2 3 8
15
14
12
10
9 11 13
P1 P2
P3 P4
Front View
of Connector
200mm / 7.87"
200mm / 7.87"
3 Meters / 9' 10"
P1 Connector P2 Connector
Pin # Signal Name Pin # Signal Name
1 Arm Mic 1 Arm Mic
2 Left Mic 2 Left Mic
3 A GND 3 A GND
4 Cam ID Bit 4 Cam ID Bit
5 P GND 5 P GND
6 +12V 6 +12V
7 SW-RX/SN-TX 7 SW-RX/SN-TX
8 IR signal 8 IR signal
9 Center Mic 9 Center Mic
10 Right Mic 10 Right Mic
11 A GND 11 A GND
12 P GND 12 P GND
13 +12V 13 +12V
14 SW-TX/SN-RX 14 SW-TX/SN-RX
15 IR return 15 IR return
P3 4 Pin mini Din P4 4 Pin mini Din
1 A GND 1 A GND
2 A GND 2 A GND
3 Luma 3 Luma
4 Chroma 4 Chroma
40mm / 1.57"
40mm / 1.57"
Page: 48
Cables
2 - 21
HDCI PowerCam Plus Adapter Cable
This cable adapts a PowerCam Plus cable to HDCI. It is HDCI to 4-pin
mini-DIN and DB-15. It can also be used with the PowerCam Primary cable
(1457-50338-001) on page 2-24 to connect PowerCam.
Length Part Number RoHS Compliant
1 ft (0.3 m) 2457-23481-001 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.
Page: 49
Integrator’s Reference Manual for Polycom HDX Systems
2 - 22
HDCI VISCA Adapter Cable
This cable connects a Polycom HDX system HDCI video input to SD cameras
with VISCA control. It is HDCI to 4-pin mini-DIN and DB-9. Standard S-Video
and DB-9 serial cables are required to connect this cable to the camera.
Length Part Number RoHS Compliant
1 ft (0.3 m) 2457-23486-001 Yes
Drawings and part numbers are provided for reference only. Polycom claims no responsibility
or liability for the quality, performance, or reliability of cables based on these reference
drawings, other than cables provided by Polycom. Contact your Polycom distributor or
Polycom Custom/Vertical Products to order cables that meet the appropriate manufacturing
tolerances, quality, and performance parameters for your application.

Question & answers

There are no questions about the Polycom 8-pin mini-DIN - DB-9 2457-10029-200 yet.

Ask a question about the Polycom 8-pin mini-DIN - DB-9 2457-10029-200

Have a question about the Polycom 8-pin mini-DIN - DB-9 2457-10029-200 but cannot find the answer in the user manual? Perhaps the users of ManualsCat.com can help you answer your question. By filling in the form below, your question will appear below the manual of the Polycom 8-pin mini-DIN - DB-9 2457-10029-200. Please make sure that you describe your difficulty with the Polycom 8-pin mini-DIN - DB-9 2457-10029-200 as precisely as you can. The more precies your question is, the higher the chances of quickly receiving an answer from another user. You will automatically be sent an e-mail to inform you when someone has reacted to your question.