Phybridge NV-FLX-04-XKIT manual

Select a language NL 100%

View a manual of the Phybridge NV-FLX-04-XKIT below. All manuals on ManualsCat.com can be viewed completely free of charge. By using the 'Select a language' button, you can choose the language of the manual you want to view.

  • Brand: Phybridge
  • Product: Wifi repeater
  • Model/name: NV-FLX-04-XKIT
  • Filetype: PDF
  • Available languages:

Table of Contents

Page: 0
FLEX4 (NV-FLX-04)
• Paired with FLEX24, FLEX8 or FLEX-Base
• 1 uplink port and 4 downlink ports
• Up to 30W PoE per downlink port
• Local power option
The FLEX4 adapter enables extended Ethernet and PoE reach beyond traditional distances
using 1, 2 or 4 pair UTP infrastructure. When paired with the FLEX24 Switch, FLEX8 Switch or
FLEX-Base Extender, the adapter delivers 10/100Mbps, symmetrical full duplex. The FLEX
offering is designed specifically to enable easy deployment over Multi-Pair UTP for reaches
beyond that of standard Ethernet eliminating the costs and disruption associated with IDF
closet requirements.
NV-FLXLK-BSE*
NV-FLX-04
Standard PoE Switch
NV-FLX-024/NV-FLX-08
Local Power Option
Multi-Pair UTP Cable
up to 2,000ft (610m)
Multi-Pair UTP Cable
up to 2,000ft (610m)
To Application
1 2 3 4 5 6 7 8
WE
3 5
1 9 11
7 15 17
13 21 23
19 27 29
25 33 35
31 39 41
37 45 47
43
4 6
2 10 12
8 16 18
14 22 24
20 28 30
26 34 36
SFP+1
SFP+2
SFP 1
SFP 2
32 40 42
38 46 48
44
Reset 24
22
20
18
16
14
12
10
8
6
4
2
23
21
19
17
15
13
11
9
7
5
3
1
RUN
ALARM
FAULT
IP ENDPOINT
IP ENDPOINT
IP ENDPOINT
IP ENDPOINT
FLEX-Base
Long Reach PoE over UTP
FLEX4 Adapter Applications
10/100Mbps (full duplex, symmetrical) & PoE++ over multi-pair UTP with 2,000ft (610M) reach.
NV-FLX-04
Local Power Option
IP ENDPOINT
IP ENDPOINT
IP ENDPOINT
IP ENDPOINT
Technical Specifications
888.901.3633 | +44 (0) 208 977 6614
www.nvtphybridge.com
Copyright 2019 NVT Phybridge
445-0019-A
*Base Extender can be powered locally for use with non-PoE switches.
Model Number FLEX4
Part Number NV-FLX-04
Dimensions
9.8cm x 9.6cm x 2.5cm (LxWxH);
3.86” x 3.78” x 0.98” (LxWxH)
Weight 214 g (7.6 oz.)
Interface: Network
Infrastructure side
(FLEX)
1 RJ45 port: UTP /STP cable (1-pair,
2-pair or 4-pair)
Interface: IEEE Side
(IP Device)
4 RJ45 ports: adapter is IEEE 802.3
af/at compliant and will negotiate
power requirements with IP end
device
Power Supply
PoE from the FLEX switch, or
external power supply; maximum
30W (over 2-pairs) each port
Power
Consumption
1.5W
DC IN
Optional (sold separately)
48-56VDC via an external AC/DC
Power Adapter (IEC Class II isolated
only)
NOTE 1: Local power supply used
must have its output isolated from
Earth potential.
NOTE 2: If voltage of local power
supply is lower than the power
voltage provided from the PoE
switch, then power on the PoE
switch should be turned off.
Operating
Temperature
-40C to +70C (-40F to +158F)
Tests conducted against international
safety standard at maximum ambient
temperatures of 60ºC at 64W and 55ºC
at 120W
Mean Time Before
Failure (MTBF)
20+ years
Humidity
10% to 95% (non-condensing) at
35° C
Page: 1
FLEX4 Quick Install Guide
1. Remove the FLEX4 from its packaging.
2. Must ensure cable is properly terminated before connecting any FLEX product.
3. Remove all legacy equipment from the UTP cable infrastructure.
NOTE: In order to avoid damage to endpoints, it is important that non-IP devices are not
connected when you connect the FLEX4.
4. Connect the Network Infrastructure cable from the FLEX24 switch, FLEX8 switch or
FLEX-Base to the FLEX4 (LRE side).
5. Using CAT5 or higher category cable, connect the endpoint to FLEX4 (Endpoint side).
To Endpoints
To LRE
(Long Reach Ethernet)
TO FLEX
100 10
SPEED
48-56V
DC IN
Link/Speed
Green:
100Mbps
Orange:
10Mbps
10/ACT 100/ACT
TO ENDPOINTS
10/ACT
PWR
1 2 3 4 100/ACT
Note the following:
All of the above instructions provide basic installation information necessary for the proper and
safe functioning of this equipment. Persons installing or maintaining this product must read all of
the safety instructions and the parts of system grounding, which are applicable to the system
being maintained. Only trained, qualified service personnel shall install or maintain this product.
• Keep these instructions with the equipment.
• Do not attempt to install or service this equipment unless you are skilled in the installation and
maintenance of electronic telecommunications equipment and have successfully completed
specific training for this equipment.
WARNING: FAILURE TO FOLLOW ALL INSTRUCTIONS MAY RESULT IN IMPROPER EQUIPMENT OPERATION AND/OR
RISK OF ELECTRICAL SHOCK.
WARNING: ANY CONNECTION TO AN OUTSIDE PLANT LEAD, AN OFF-PREMISE APPLICATION, OR ANY OTHER
EXPOSED PLANT APPLICATION MAY RESULT IN A FIRE OR SHOCK HAZARD, AND/OR DEFECTIVE OPERATION, AND/OR
EQUIPMENT DAMAGE.
Safety Warnings and Precautions
Compliance and Environmental Information
All the compliance and environmental information is available on our website
www.nvtphybridge.com
*Note: PoE Power is shared on all 4 ports of FLEX4, to a max of 30 Watts output per port.
Support and Warranty
Technical Support
The NVT Phybridge Technical Support Group is available to assist you with product installation,
configuration, monitoring and troubleshooting procedures. Should you experience trouble with
this equipment or for repair or warranty information, please contact NVT Phybridge at
www.nvtphybridge.com/support/ or directly through email at support@nvtphybridge.com
Warranty: The FLEX adapters are backed by NVT Phybridge’s award-winning customer support
and 5-year warranty.
• Refer to the FLEX24 or FLEX8 Quick Install Guides under “Safety Warnings” for the FLEX adapters
• Reportez-vous aux Quick Install Guides FLEX24 ou FLEX8 sous "Safety Warnings" pour les adaptateurs FLEX
• Beachten Sie die FLEX24- oder FLEX8- Quick Install Guides unter "Safety Warnings” für die FLEX-Adapter
• Consulte las Quick Install Guides FLEX24 o FLEX8 bajo "Safety Warnings" para los adaptadores FLEX
• Katso FLEX24- tai FLEX8 Quick Install Guides FLEX-sovittimien "Safety Warnings" alla
• Raadpleeg de FLEX24 of FLEX8 Quick Install Guides onder "Safety Warnings" voor de FLEX-adapters
• Se FLEX24 eller FLEX8 Quick Install Guides under "Safety Warnings" för FLEX-adaptrarna
• Se FLEX24 eller FLEX8 Quick Install Guides under "Safety Warnings" for FLEX-adaptere
• Ανατρέξτε στους οδηγούς FLEX24 ή FLEX8 Quick Install Guides στην ενότητα "Safety Warnings" για τους προσαρμογείς FLEX
• Fare riferimento alla sezione FLEX24 o FLEX8 Quick Install Guides sotto "Safety Warnings" per gli adattatori FLEX
• Consulte o FLEX24 ou FLEX8 Quick Install Guides em "Safety Warnings" para os adaptadores FLEX
• Irreferi għall-FLEX24 jew FLEX8 Quick Install Guides taħt "Safety Warnings" għall-adapters FLEX
• Vaadake FLEX24 või FLEX8 Quick Install Guides alusel "Safety Warnings" FLEX adapterid
• A FLEX adapterek "Safety Warnings" című részében olvassa el a FLEX24 vagy a FLEX8 Quick Install Guides című részt
• Nanašajo na FLEX24 ali FLEX8 Quick Install Guides pod "Safety Warnings" za FLEX adapterji
• Další informace naleznete v příručkách FLEX24 nebo FLEX8 Quick Install Guides v části "Safety Warnings" pro adaptéry FLEX
• Kreiptis į FLEX24 ar FLEX8 Quick Install Guides pagal "Safety Warnings" Už FLEX adapteriai
• Skatiet FLEX24 vai FLEX8 Quick Install Guides zem "Safety Warnings", lai FLEX adapteri
• Pozrite si FLEX24 alebo FLEX8 Quick Install Guides v časti "Safety Warnings" pre adaptéry FLEX
• Sjá FLEX24 eða FLEX8 Quick Install Guides undir "Safety Warnings" fyrir FLEX-millistykki
• Zobacz FLEX24 lub FLEX8 Quick Install Guides w sekcji "Safety Warnings" w przypadku adapterów FLEX
• Se FLEX24 eller FLEX8 Quick Install Guides under "Safety Warnings" for FLEX-adaptere
• Consultați ghidurile FLEX24 sau FLEX8 Quick Install Guides din secțiunea "Safety Warnings" pentru adaptoarele FLEX
• Обърнете се към FLEX24 или FLEX8 Quick Install Guides в "Safety Warnings" за адаптери FLEX
PoE Power Available to FLEX4
888.901.3633 | +44 (0) 208 977 6614
www.nvtphybridge.com
Copyright 2019 NVT Phybridge
445-0019-A
FLEX4
20ft
(6m)
250ft
(76m)
500ft
(152m)
750ft
(228m)
1,000ft
(305m)
1,250ft
(381m)
1,500ft
(457m)
1,750ft
(533m)
2,000ft
(610m)
Cat6 4-Pairs 50W 48 46 44 42 39 37 35 33
Cat6 2-Pairs 30W 30 29 28 26 24 22 20 18
Cat5e 4-Pairs 50W 47 44 41 38 35 33 30 27
Cat5e 2-Pairs 30W 30 28 25 23 20 18 15 12

Question & answers

There are no questions about the Phybridge NV-FLX-04-XKIT yet.

Ask a question about the Phybridge NV-FLX-04-XKIT

Have a question about the Phybridge NV-FLX-04-XKIT but cannot find the answer in the user manual? Perhaps the users of ManualsCat.com can help you answer your question. By filling in the form below, your question will appear below the manual of the Phybridge NV-FLX-04-XKIT. Please make sure that you describe your difficulty with the Phybridge NV-FLX-04-XKIT as precisely as you can. The more precies your question is, the higher the chances of quickly receiving an answer from another user. You will automatically be sent an e-mail to inform you when someone has reacted to your question.