Page: 6
7
manuale d’uso user’s manual
Regolazione riscaldamento
La regolazione della temperatura
dell’acqua di riscaldamento si effettua
agendo sui tasti 6.
Si ottiene una temperatura variabile da
35°C a 82°C.
Il valore prescelto viene visualizzato sul
display lampeggiante.
Adjusting the heating
It is possible to set the temperature
of the heating water by pressing the
buttons 6.
The temperature that may be obtained
which varies from 35°C to 82°C.
The value set previously will flash on the
display.
OK
ESC
Procedura di spegnimento
Per spegnere la caldaia premere il tasto
ON/OFF, il display si spegne.
La funzione antigelo è attiva.
IMPORTANTE!!
Per spegnere completamente la caldaia
portare l’interruttore elettrico esterno in
posizione OFF. Chiudere il rubinetto del
gas.
Switching off the boiler
To switch off the boiler press the ON/
OFF button, the display will switch off.
The Anti-frost Function is allready ac-
tive.
ATTENTION!!
Switch off the boiler completely by
switching the external electrical switch
to the OFF position. Shut off the gas
valve..
OK
ESC
OK
ESC
Regolazione temperatura sanitario
È possibile regolare la temperatura
dell’acqua sanitaria agendo sui tasti 1,
si ottiene una temperatura variabile da
36°C a 60°C.
Il valore prescelto viene visualizzato sul
display lampeggiante.
Domestic hot water temperature
adjustement
It is possible to set the temperature of
the domestic hot water by pressing
the buttons 1 a temperature may be
obtained which varies from 36°C to
60°C.
The value set previously will flash on the
display.
OK
ESC
Interruzione riscaldamento
Per interrompere il riscaldamento
premere il tasto MODE 4, dal display
scompare il simbolo . La caldaia
rimarrà in funzionamento estivo per
la sola richiesta di acqua calda ad uso
sanitario, indicando la temperatura
impostata.
Switching off the heating
To switch off the heating, press the
MODE button 4; the heating operation
symbol will disappear from the
display. The Mode button can be
used to keep the domestic hot water
production process active or to place it
in standby (modes deactivated).
In the figure below the boiler remains
active only for the production of
domestic hot water, indicating the set
temperature.
Page: 7
8
manuale d’uso user’s manual
Condizioni di arresto dell’apparecchio
La caldaia è protetta da malfunzionamento tramite controlli interni
da parte della scheda elettronica, che opera se necessario blocco
di sicurezza. In caso di blocco viene visualizzato sul display del
pannello comandi un codice che si riferisce al tipo di arresto ed alla
causa che lo ha generato.
Si possono verificare due tipi di arresto.
Arresto di sicurezza
Questo tipo di errore è di tipo “volatile”, ciò significa che
viene automaticamente rimosso al cessare della causa
che lo aveva provocato.
Sul display viene visualizzato il codice, che lampeggia
alternativamente alla scritta Err, (es. Err/110) ed appare il
simbolo - vedi Tabella Errori.
Non appena la causa dell’arresto scompare, la caldaia
riparte e riprende il suo normale funzionamento.
Se la caldaia segnalerà ancora l’arresto di sicurezza, spegnere la
caldaia. Portare l’interruttore elettrico esterno in posizione OFF,
chiudere il rubinetto del gas e contattare un tecnico qualificato.
Arresto di sicurezza per insufficiente pressione acqua
- modelli FF
In caso di insufficiente pressione dell’acqua nel circuito
riscaldamento la caldaia segnala un arresto di sicurezza
Err/108 - vedi Tabella Errori.
Verificare la pressione sull’idrometro e chiudere il
rubinetto non appena si raggiunge 1 - 1,5 bar.
E’ possibile ripristinare il sistema reintegrando l’acqua
attraverso il rubinetto di riempimento posto sotto la
caldaia.
Se la richiesta di reintegro dovesse essere frequente, spegnere la
caldaia, portare l’interruttore elettrico esterno in posizione OFF,
chiudere il rubinetto del gas e contattare un tecnico qualificato per
verificare la presenza di eventuali perdite di acqua.
Arresto di sicurezza per insufficiente circolazione acqua
- modelli FF - CF
In caso di insufficiente circolazione dell’acqua nel
circuito riscaldamento la caldaia segnala un arresto di
sicurezza Err/103 - vedi Tabella Errori.
Verificare la pressione sull’idrometro e chiudere il
rubinetto non appena si raggiunge 1 - 1,5 bar.
E’ possibile ripristinare il sistema reintegrando l’acqua
attraverso il rubinetto di riempimento posto sotto la caldaia.
Se la richiesta di reintegro dovesse essere frequente, spegnere la
caldaia, portare l’interruttore elettrico esterno in posizione OFF,
chiudere il rubinetto del gas e contattare un tecnico qualificato per
verificare la presenza di eventuali perdite di acqua.
Blocco di funzionamento
Questo tipo di errore è di tipo “non volatile”, ciò significa che non
viene automaticamente rimosso.
Suldisplayvienevisualizzatoilcodice,chelampeggiaalternativamente
alla scritta Err, es. Err/501 e compare il simbolo .
In questo caso la caldaia non riparte automaticamente e potrà essere
sbloccata solo tramite la pressione del tasto .
Dopo alcuni tentativi di sblocco, se il problema si ripete è necessario
far intervenire un tecnico qualificato.
Appliance shut-off conditions
The boiler is protected from malfunctions by means of internal
checks performed by the electronic P.C.B., which stops the boiler
from operating if necessary. In the event of the boiler being shut off
in this manner, a code appears on the control panel display which
refers to the type of shut-off and the reason behind it.
Two types of shut-off may occur:
Safety shut-off
This type of error is“volatile”, which means that the boiler
starts up again automatically as soon as the problem
which caused the shut-off is removed. On the display
flash“Err”and the error code (es. Err/110) and appear the
symbol - see the error table.
In fact, soon as the cause of the shut-off disappears, the
boiler starts up again and continues to operate normally.
While the boiler is shut off for safety reasons, it is possible to attempt
to restore normal operation by switching the appliance off and on
again using the ON/OFF button on the control panel.
If the boiler still indicates a safety shut-off, switch it off. Make sure the
external electric switch is in the OFF position, shut off the gas valve
and contact a qualified technician.
Safety shut-off due to insufficient water pressure
- FF model
If the water pressure inside the heating circuit is
insufficient, the boiler will perform a safety shut-off.
On the display flash “Err” and the code - Err/108 - for
Insufficient water pressure -- see the error table.
Check the water pressure on the pressure gauge and
make sure that is between 0.6 and1.5 bar when the
system is cold. If the pressure is just under the minimum refill the
system by open the valve under the boiler.
If the pressure drops very frequently, there may be a water leak at
some point in the system. If this is the case a plumber should be
contacted.
Safety shut-off due to insufficient water circulation
- FF and CF models
If the water circulation inside the heating circuit is
insufficient, the boiler will perform a safety shut-off.
On the display flash “Err” and the code - Err/103 - for
Insufficient circulation -- see the error table.
Check the water pressure on the pressure gauge and
make sure that is between 0.6 and1.5 bar when the
system is cold. If the pressure is just under the minimum refill the
system by open the valve under the boiler.
If the pressure drops very frequently, there may be a water leak at
some point in the system. If this is the case a plumber should be
contacted.
Operation shutdown
This type of error is“non-volatile”, which means that it is not removed
automatically.
On the display flash Err, the error code -es. Err/501 , and appear the
symbol .
In this case the boiler does not restart automatically, but it may
be reset by pressing the button. If the problem manifests
itself again after several attempts to reset the appliance, contact a
qualified technician.
IMPORTANTE
Se il blocco si ripete con frequenza, si consiglia l’intervento del Centro di
Assistenza Tecnica autorizzato.
Per motivi di sicurezza, la caldaia consentirà comunque un numero
massimo di 5 riarmi (pressioni del tasto ) in 15 minuti.
Nel caso in cui il blocco sia sporadico o isolato non costituisce un
problema.
Important
If this shutdown occurs frequently, contact an authorised service centre
for assistance. For safety reasons, the boiler will allow a maximum of 5
reset operations to take place in 15 minutes (individual presses of the
button).
If the shutdown is occasional or an isolated event, this is not
Necessarily a problem.
Page: 8
9
manuale d’uso user’s manual
OK
ESC
Descrizione Display Description
Sovratemperatura
Attendere che il simbolo inizi a lampeggiare prima di premere
il tasto RESET.
1 01
1 01
Overheating
Wait until the symbol starts flashing before you press the RESET
button.
Circolazione Insufficiente
Attendere che il simbolo inizi a lampeggiare prima di premer
eil tasto RESET.
1 03
1 03
Insufficient circulation
Wait until the symbol starts flashing before you press the RESET
button.
1 04
1 04
1 05
1 05
1 06
1 06
1 07
1 07
Mancanza acqua (richiesto riempimento) - modello FF 1 08
1 08 Insufficient water (request filling) - model FF
Circolazione Insufficiente
Attendere che il simbolo inizi a lampeggiare prima di premer
eil tasto RESET.
1 17
1 17
Insufficient circulation
Wait until the symbol starts flashing before you press the RESET
button.
Errore scheda 3 05
3 05 P.C.B. error
Errore scheda 3 06
3 06 P.C.B. error
Errore scheda 3 07
3 07 P.C.B. error
Mancanza fiamma 5 01
5 01 No flame detection
Intervento Sonda Fumi 6 01
6 01 Fume sensor error
Operation shutdown error table
Tabella Errori per Blocco di Funzionamento
Temporary Shut-Off due to defective flue gas discharge (CF) 601
This device causes the boiler to shut down in the event of an anomaly
in the flue gas discharge. The appliance shutdown is temporary and
is signalled by error code 601
601..
After 12 minutes, the boiler begins the ignition procedure; if normal
conditions have been restored, the boiler operates as normal. If not,
the boiler shuts down and the cycle is repeated.
WARNING!
In the event of a malfunction or if repeated intervention is re-
quired, switch the boiler off, shut off the electricity supply by
turning the external switch to the OFF position and shut off the
gas valve. Contact the Technical Assistance Service or a qualified
technician in order to repair the flue gas discharge fault once the
cause of the malfunction is detected.
Arresto Temporaneo per anomalia evacuazione fumi
(24 CF) 601
601
Tale controllo blocca la caldaia in caso di anomalia di evacuazione
fumi. Il blocco dell’apparecchio è temporaneo ed è segnalato con
codice di errore 601
601. Dopo 12 minuti la caldaia inizia la procedura di
accensione; se le condizioni sono ritornate alla normalità prosegue
nel funzionamento in caso contrario la caldaia si blocca ed il ciclo si
ripete.
ATTENZIONE!
In caso di malfunzionamento o di interventi ripetuti spegnere la
caldaia, togliere l’alimentazione elettrica portando l’interruttore
esterno in posizione OFF, chiudere il rubinetto del gas e
contattare il Servizio Assistenza o un tecnico qualificato per
rimediare al difetto di evacuazione dei fumi verificando la causa
del malfunzionamento.

Question & answers

There are no questions about the Ariston Thermo EGIS PLUS 24 FF GPL yet.

Ask a question about the Ariston Thermo EGIS PLUS 24 FF GPL

Have a question about the Ariston Thermo EGIS PLUS 24 FF GPL but cannot find the answer in the user manual? Perhaps the users of ManualsCat.com can help you answer your question. By filling in the form below, your question will appear below the manual of the Ariston Thermo EGIS PLUS 24 FF GPL. Please make sure that you describe your difficulty with the Ariston Thermo EGIS PLUS 24 FF GPL as precisely as you can. The more precies your question is, the higher the chances of quickly receiving an answer from another user. You will automatically be sent an e-mail to inform you when someone has reacted to your question.